MP-90 · MACHINING AND SEALS

Static O-Ring Gland Screen

Screen a static O-ring gland with user-entered seal cross section, gland depth, width, and diameter-based stretch assumptions.

Preliminary design support. Your inputs and results stay in this browser.

INPUTS

Next decision: Calculate hydraulic cylinder force

Want to learn more? Seals and Cylinders: Preliminary Fluid-Power Boundaries

WHAT THIS SCREEN ANSWERS

Static O-ring glands depend on cross-section squeeze, stretch, material, fluid, temperature, pressure, surface, and extrusion risk. The page makes basic gland geometry relationships visible without selecting a seal or claiming a pressure rating. The calculation earns its place by narrowing a specific design choice.

Exact gland tables, material compatibility, pressure, gap, surface finish, installation, and thermal conditions can govern. Confirm current manufacturer data, seal material, fluid, temperature, pressure, hardware geometry, installation, and qualified review. It may matter before the nominal value does.

Static O-ring glands depend on cross-section squeeze, stretch, material, fluid, temperature, pressure, surface, and extrusion risk. Exact gland tables, material compatibility, pressure, gap, surface finish, installation, and thermal conditions can govern. Do not let a convenient default become an undocumented design requirement.

The page makes basic gland geometry relationships visible without selecting a seal or claiming a pressure rating. Confirm current manufacturer data, seal material, fluid, temperature, pressure, hardware geometry, installation, and qualified review. The decision remains specific to this application because static o-ring glands depend on cross-section squeeze, stretch, material, fluid, temperature, pressure, surface, and extrusion risk. Document what was assumed before the concept becomes a release.